Test items |
Detection range |
According to the standard |
|||
Cryogenic test |
Temperature: RT ~ -70 ℃ |
GB / T 2423.1 ; IEC 60068-2-1 ... |
|||
High temperature test |
Temperature: RT ~ 300 ℃ |
GB / T 2423.2; IEC 60068-2-2 ... |
|||
Constant temperature and humidity test |
Temperature range: -40 ℃ ~ 150 ℃; humidity range: 20 ~ 98% RH. |
GB / T 2423.3; IEC 60068-2-78 ... |
|||
Alternating damp heat test |
Temperature range: -40 ℃ ~ 150 ℃; humidity range: 20 ~ 98% RH. |
GB / T 2423.4; IEC 60068-2-30 ... |
|||
Hot and cold impact test |
Temperature range: -65 ℃ ~ 150 ℃; High temperature setting range: +60 ℃ ~ + 150 ℃; Low temperature setting range: 0 ℃ ~ -65 ℃; Temperature change rate: ≤3Min. |
GB / T 2423.22; EC 60068-2-14; EIA-364-32 ... |
|||
Rapid temperature change test |
Temperature range: -70 ℃ ~ 150 ℃; humidity range: 25% ~ 98% RH; Maximum temperature rate of change: 15 ℃ / min max. |
GB / T2423.22; IEC60068-2-14 ... |
|||
UV UV aging test |
Lamp Type: UVA-340, UVA-351, UVB-313; Temperature range: light: 50-85 ℃, condensation: 40-60 ℃; Irradiance: 0.35 ~ 1.55W / m2 / nm (UVA-340, UVA-351); 0.35 ~ 1.23W / m2 / nm (UVB-313). |
ISO 4892.3; GB / T 16422.3; ASTM G 154; ASTM D4329 ... |
|||
Xenon test |
Temperature and humidity range: 10 ℃ ~ 70 ℃, 65 ~ 98% RH; Test wavelength: 300nm ~ 800nm. |
GB / T2423.24; ISO 4892.2; GB / T 16422.2; ASTM G 155; ASTM D 4459 ... |
|||
Salt spray test |
NSS, ASS, CASS. |
GB / T 2423.17; IEC 60068-2-11; GB / T 10125; ISO 9227; ASTM B 117; ISO 10289; GB / T6461 ... |
|||
Gas corrosion test |
Gas type: SO2, H2S, NO2, Cl2; Gas concentration: 10ppb ~ 100ppm; temperature range: 0 ~ 50 ℃; humidity range: 10% ~ 98% RH. |
EIA-364-65; GB / T 2423.51; IEC 60068-2-60 ... |
|||
IP level test (dust and water) |
IPX0 ~ IPX8; IP0X ~ IP6X. |
IEC / EN60529; GB / T 4208; IEC 60598 ... |
|||
Ozone aging test |
0 --- 500pphm. |
GB / T 7762 ; ISO 1431-1 ... |
|||
Test items |
Detection range |
According to the standard |
Mechanical vibration test |
Maximum displacement:40mm p-p;Table size: 600mm × 600mm; maximum speed: 2.2m / s; maximum acceleration: 100g; frequency range: 1-3000Hz. |
GB/T 2423.56; IEC 60068-2-64; ASTM D4728 … |
Mechanical impact test |
Maximum load: 200Kg; Maximum acceleration: 3000g; Maximum drop height: 1600mm; Table size: 800mm × 650mm; Shock wave: half sine, trapezoidal wave, after the peak sawtooth wave. |
GB/T2423.5 ;IEC60068-2-27;EIA-364-27… |
Drop test |
Drop height: 300mm ~ 1500mm; specimen maximum quality: 85Kg. |
GB/T 2423.8 ;ISO 2248 ; GB/T 4857.5… |
Alcohol, eraser, pencil friction test |
Friction speed: 10 ~ 120 times / min Rubbing methods: alcohol, rubber. |
GB/T 6739 ; ASTM D 3363… |
Adhesion 100 test |
Distance: 1mm, 2mm. |
GB/T9286;ASTM D 3359… |
Plug test |
Test pressure:0~500g Weight; test speed: 0 ~ 64 times / min; Test travel: 0 ~ 50mm; Number of tests: 0 ~ 999999 times. |
EIA-364-13… |
Wire swing test |
Test times: 0 ~ 999999 times; Bending angle: 10 ° ~ 180 ° adjustable; Bending rate:10~60rpm ;Load weight:50g、100g、200g、300g、500g。 |
EIA-364-41… |
Test items |
Detection range |
According to the standard |
HALT&HASS &HASA |
Temperature range: -100 ℃ ~ +200 ℃; Temperature rate of change: 70 ℃ / min Max; Vibration acceleration: 60grms Max; Vibration frequency range: 2Hz ~ 10000Hz; Vibration table load:408.23Kg Max;Shaker size:914mm×914mm。 |
-- |
vibration&temperature&humidity (Synthesis) |
Temperature: -70 ℃ ~ 150 ℃; temperature change rate: 15 ℃ / min; humidity:25%~98%RH(20℃~80℃); Vibration: Electromagnetic Vibration, Uniaxial, Random, Sine,(LDS-V850-440 LPT 750COMBO); Equipment size: width 1.0m × height 1.2 m × depth1.0 m (Thermostat) ;Vibration table size:750 × 750 mm。 |
GJB1032-90 |